west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "fluoroscopy" 3 results
  • A comparative study of spinal robot-assisted and traditional fluoroscopy-assisted percutaneous reduction and internal fixation for single-level thoracolumbar fractures without neurological symptoms

    ObjectiveTo compare the effectiveness and screw planting accuracy of percutaneous reduction and internal fixation with robot and traditional fluoroscopy-assisted in the treatment of single-level thoracolumbar fractures without neurological symptoms.MethodsThe clinical data of 58 patients with single-level thoracolumbar fractures without neurological symptoms between December 2016 and January 2018 were retrospectively analysed. According to different surgical methods, the patients were divided into group A (28 cases underwent robot-assisted percutaneous reduction and internal fixation) and group B (30 cases underwent fluoroscopy-assisted percutaneous reduction and internal fixation). There was no neurological symptoms, other fractures or organ injuries in the two groups. There was no significant difference in general data of age, gender, fracture location, AO classification, time from injury to surgery, and preoperative vertebral anterior height ratio, sagittal Cobb angle, visual analogue scale (VAS) score, and Oswestry disability index (ODI) score between the two groups (P>0.05). The screw placement time, operation time, intraoperative blood loss, intraoperative fluoroscopy frequency, hospitalization time, operation cost, postoperative complications, VAS score, ODI score, anterior vertebral height ratio, and sagittal Cobb angle before operation, at 3 days, 6 months after operation, and at last follow-up were recorded and compared between the two groups. The accuracy of the pedicle screw placement was evaluated by Neo’s criteria.ResultsThe screw placement time, operation time, and intraoperative fluoroscopy frequency of group A were significantly less than those of group B, and the operation cost was significantly higher than that of group B (P<0.05). But there was no significant difference in intraoperative blood loss and hospitalization time between the two groups (P>0.05). Both groups were followed up 12-24 months, with an average of 15.2 months. The accuracy rate of screw placement in groups A and B was 93.75% (150/160) and 84.71% (144/170), respectively, and the difference was significant (χ2=5.820, P=0.008). Except for 1 case of postoperative superficial infection in group A and wound healing after dressing change, there was no complication such as neurovascular injury, screw loosening and fracture in both groups, and there was no significant difference in the incidence of complications between the two groups (χ2=0.625, P=0.547). The anterior vertebral height ratio, sagittal Cobb angle, VAS score, and ODI score of the two groups were significantly improved (P<0.05); there was no significant difference between the two groups at all time points after operation (P>0.05).ConclusionThe spinal robot and traditional fluoroscopy-assisted percutaneous reduction and internal fixation can both achieve satisfactory effectiveness in the treatment of single-level thoracolumbar fractures without neurological symptoms. However, the former has higher accuracy, fewer fluoroscopy times, shorter time of screw placement, and lower technical requirements for the operator. It has wide application potential.

    Release date:2020-02-18 09:10 Export PDF Favorites Scan
  • Treatment of irreducible intertrochanteric femoral fracture in elderly by folding top technique combined with right-angle pliers prying and pulling under G-arm X-ray fluoroscopy

    Objective To explore the effectiveness of irreducible intertrochanteric femoral fracture in the elderly by treating with folding top technique and right-angle pliers prying and pulling under G-arm X-ray fluoroscopy. Methods The clinical data of 74 elderly patients with irreducible intertrochanteric femoral fracture admitted between February 2016 and December 2022 and met the selection criteria were retrospectively analyzed. Among them, 38 cases were treated with folding top technique combined with right-angle pliers prying and pulling under G-arm X-ray fluoroscopy and intramedullary nailing fixation (study group), and 36 cases were treated with limited open reduction combined with other reduction methods and intramedullary nailing fixation (control group). There was no significant difference in baseline data between the two groups, such as age, gender, cause of injury, affected side and classification of fractures, complicated medical diseases, and time from injury to operation (P>0.05). The operation time, intraoperative blood loss, hospital stay, fracture reduction time, fracture healing time, and complications of the two groups were recorded and compared. The quality of fracture reduction was evaluated by Baumgaertner et al. and Chang et al. fracture reduction standards. ResultsPatients in both groups were followed up 10-14 months, with an average of 12 months. The operation time and intraoperative blood loss in the study group were significantly less than those in the control group (P<0.05), there was no significant difference in hospital stay between the two groups (P>0.05). At 2 days after operation, according to the fracture reduction standards of Baumgaertner et al. and CHANG Shimin et al., the quality of fracture reduction in the study group was better than that in the control group, and the fracture reduction time in the study group was shorter than that in the control group, with significant differences (P<0.05). After operation, the fractures of the two groups all healed, and there was no significant difference in healing time between the two groups (P>0.05). During the follow-up, there was no complication such as incision infection, internal fixation failure, deep venous thrombosis of lower limbs, intramedullary nail breakage, spiral blade cutting, or hip varus in the two groups, except for 2 cases of coxa vara in the control group. Conclusion For the irreducible intertrochanteric femoral fracture, using folding top technique combined with right-angle pliers prying and pulling under G-arm X-ray fluoroscopy can obviously shorten the operation time, reduce the intraoperative blood loss, and improve the quality of fracture reduction.

    Release date: Export PDF Favorites Scan
  • A new fluoroscopic view to evaluate the medial and lateral articular reduction quality in patella fractures during internal fixation

    Objective To introduce a new fluoroscopic method for assessing the quality of medial and lateral joint surface reduction during internal fixation of patellar fractures and to summarize the clinical outcomes of patients treated using this method. Methods A retrospective analysis was conducted on the clinical data of 52 patients with patellar fractures treated between January 2018 and January 2022 who met the inclusion criteria. There were 27 male and 25 female patients, aged 21-75 years, with an average age of 62 years. The types of patellar fractures included 9 transverse fractures, 37 comminuted fractures, and 6 longitudinal fractures. According to the AO/Orthopaedic Trauma Association (AO-OTA)-2018 fracture classification, there were 21 cases of type 34A, 6 cases of type 34B, and 25 cases of type 34C. The time from injury to operation ranged from 1 to 5 days, with an average of 2.3 days. Treatments included internal fixation with hollow screws or hollow screw tension bands, with or without anchor repair. During operation, the medial and lateral joint surfaces of the patella were observed using the tangential fluoroscopic method to assess the smoothness of reduction of the median ridge, lateral joint surface, medial joint surface, and lateral joint edge. Patients were followed up regularly, and X-ray films were taken to observe fracture healing. Knee joint range of motion, Böstman score, and Lysholm score were used to evaluate functional recovery. Results The tangential fluoroscopic method for the medial and lateral joint surfaces of the patella during operation showed satisfactory reduction of the joint surfaces and good positioning of the implants. All patients were followed up 12-16 months, with an average of 13.4 months. During the follow-up, fracture displacement occurred in 1 case and titanium cable breakage in 1 case. All patella fractures healed successfully, with a healing time of 8-16 weeks (mean, 11.4 weeks). At last follow-up, knee joint range of motion ranged from 120° to 140°, with an average of 136°. The Böstman score ranged from 20 to 30, with an average of 28, yielding excellent results in 45 cases and good results in 7 cases. The Lysholm score ranged from 88 to 100, with an average of 93, yielding excellent results in 40 cases and good results in 12 cases. Conclusion The intraoperative application of the tangential fluoroscopic method for the medial and lateral joint surfaces of the patella can quickly determine the fluoroscopic plane of the patella, accurately assess the quality of fracture reduction and the position of internal fixator, thereby improving effectiveness.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content